เจ้าของร้านค้านี้ ไม่ได้เข้าสู่ระบบเป็นระยะเวลา 38 วัน แล้ว
ไฮไลท์
FCM-1(A) Control Module: The FCM-1(A) Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes,
speakers, etc.). Addressability allows the FCM-1(A) to be activated, either manually or through panel programming, จำหน่าย จำหน่ายในราคาปลีกและส่ง โทร. 02-125-7009
ข้อมูล
น้ำหนัก
บาร์โค้ด
ลงสินค้า
อัพเดทล่าสุด
รายละเอียดสินค้า
พีเอสโปรเฟสเทรดดิ้ง นำเสนอ FCM-1(A) Control Module: The FCM-1(A) Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be activated, either manually or through panel programming, FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features ï Built-in type identification automatically identifies these devices to the control panel. ï Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). ï Integral LED “blinks” green each time a communication is received from the control panel and turns on in steady red when activated. ï LED blink may be deselected globally (affects all devices). ï High noise immunity (EMF/RFI). ï The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). ï Wide viewing angle of LED. ï SEMS screws with clamping plates for wiring ease. ï Direct-dial entry of address 01– 159 for FlashScan loops, 01 – 99 for CLIP mode loops. ï Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be programmed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan® releasing applications. Construction ï The face plate is made of off-white heat-resistant plastic. ï Controls include two rotary switches for direct-dial entry of address (01-159). ï The FCM-1(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will disconnect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. Specifications for FCM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 μA direct poll, 375 μA group poll with LED flashing, 485 μA Max. (LED flashing, NAC shorted.) FCM-1(A) 7000cov.JPG Page 2 of 2 — DN-6724:B3 ï 2/17/2011 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, Made in the U.S. A. Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using

สามารถติดต่อขอใบเสนอราคาได้ที่ สายด่วน 02-125-7009 หรือ แอดไลน์ @765svqyv
 
เงื่อนไขอื่นๆ
Tags

วิธีการสั่งซื้อสินค้า


วิธีการสั่งซื้อสินค้ากับ พีเอส โปรเฟสเทรดดิ้ง

1. โทรสั่งซื้อสินค้าได้ที่ เบอร์โทร 02 045 6799 หรือ แอดไลน์ไอดี @765svqyv (หรือสแกนคิวอาร์โค้ดเพิ่มเพื่อนได้ที่หน้าสินค้า และ หน้าเว็บ)


2. สอบถามรายการสินค้าได้ที่แอดมินและฝ่ายขาย ให้ข้อมูล ชื่อ ที่อยู่ เบอร์โทรติดต่อกับพนักงาน เพื่อทำใบเสนอราคา

3. หลังจากได้รับใบเสนอราคาแล้ว ทำการสั่งซื้อและโอนยอด

4. หลังจากชำระค่าสินค้าเรียบร้อยแล้ว สินค้าจะถูกจัดส่งภายใน 1-3 วันทำการ กรณีสินค้าพร้อมส่ง


ส่งตรง ส่งไว ไว้ใจ "พีเอสโปรเฟสเทรดดิ้ง"

วิธีการชำระเงิน

ร้านค้านี้ยังไม่ได้กำหนดวิธีการชำระเงิน กรุณา ติดต่อกับทางร้าน เกี่ยวกับรายละเอียดในการชำระเงิน
ทางร้านยังไม่ได้ทำการเพิ่มบัญชีรับเงิน กรุณาติดต่อ เจ้าของร้าน

นโยบายการเปลี่ยนหรือคืนสินค้า

นโยบายการเปลี่ยนหรือคืนสินค้า ภายใน 7 วัน
รายการสั่งซื้อของฉัน
เข้าสู่ระบบด้วย
เข้าสู่ระบบ
สมัครสมาชิก

ยังไม่มีบัญชีเทพ สร้างบัญชีใหม่ ไม่มีค่าใช้จ่าย
สมัครสมาชิก (ฟรี)
รายการสั่งซื้อของฉัน
ข้อมูลร้านค้านี้
ร้านPS-FIRE ONLINE SALES
PS-FIRE ONLINE SALES
พีเอสไฟร์ (ps-fire) ศูนย์รวมอุปกรณ์ป้องกันและระงับเหตุเพลิงไหม้ อุปกรณ์งานกู้ภัย และอุปกรณ์เพื่อความปลอดภัยทุกชนิด ในราคาส่ง 🔥บริการงานติดตั้ง ตรวจเช็ค ซ่อมแซมระบบดับเพลิงทุกชนิด ควบคุมงานโดยวิศวกรผู้ชำนาญการ 🔥ให้คำปรึกษาแก่หน่วยงานทุกองค์กร อาคารสูง บุคคล/นิติบุคคล ผู้รับเหมา และผู้จำหน่ายต่อ
เบอร์โทร :
อีเมล : psfireonline@gmail.com
ส่งข้อความติดต่อร้าน
เกี่ยวกับร้านค้านี้
สินค้าที่ดูล่าสุด
ดูสินค้าทั้งหมดในร้าน
สินค้าที่ดูล่าสุด
บันทึกเป็นร้านโปรด
Join เป็นสมาชิกร้าน
แชร์หน้านี้
แชร์หน้านี้

TOP เลื่อนขึ้นบนสุด
73a8d042c308af21046764ba4d5b7064.png

หมวดหมู่สินค้า

อุปกรณ์แจ้งเตือนเหตุ [118]

ระบบสมาชิก

พูดคุย-สอบถาม